| Model |
Number
of Tubes |
Water tank
capacity (L) |
Dimensions
(mm) |
Effective
absorbtion
area (m2) |
Empty
weight
(kg) |
Operational
weight (kg) |
| BRJ90L-70/1900-9 |
9 |
90 |
1280 x 1565 x 1666 |
1.71 |
74 |
158 |
| BRJ120L-70/1900-12 |
12 |
120 |
1610 x 1565 x 1666 |
2.26 |
92 |
202 |
| BRJ150L-70/1900-15 |
15 |
150 |
1940 x 1565 x 1666 |
2.81 |
110 |
246 |
| BRJ200L-70/1900-20 |
20 |
200 |
2590 x 1565 x 1666 |
3.27 |
147 |
347 |
| |
|
|
|
|
|
|
| Water tank and Supporting stand |
|
|
|
|
| Material of inner tank |
|
Steel with porcelain coating |
|
|
|
| Material of outer tank |
|
Steel coated with Al & Zn |
|
|
|
| Operational pressure |
|
To 0.6 Mpa |
|
|
|
|
| Inlet and outlet connections |
G 1/2, G 1/2 |
|
|
|
|
| Electric heating element |
|
1500W / ~240V / 50 Hz |
|
|
|
| Heat - insulation |
|
Polyurethane foam 55mm without freon |
|
|
| Material of Supporting stand |
Aluminium alloy |
|
|
|
| Working Temp. |
|
From -40 °C to +100 °C |
|
|
|
| |
|
|
|
|
|
|
| Absorber with Refelctor |
|
|
|
|
|
| Tube size |
Ø70mm-1900mm |
Absorbing coefficient |
>0.92 |
|
| Tube glass thickness |
2.5mm |
|
Emission coefficient |
|
< 0.08 by 80 °C |
| Dilatability |
3.3 x 10-6 m/k |
High vacuum |
|
<5x10-3 Pa |
| Mechanical ruggedness |
0.8 MPa |
|
Tube's material |
|
High quality |
| Stagnation Temp. |
250 °C |
|
|
|
borosilicate glass |
| Hail and ice |
To 35mm |
|
Coating |
|
Selective absorber |
| Operational Temp. |
To 100 °C |
Absorber's temperature loss |
<0.8W/M2k |
| |
|
|
|
|
|
|
| Control unit AIMI |
|
|
|
|
|
|
| Power supply |
|
|
~240V / 50 Hz |
|
|
|
| Consumption |
|
|
<5W |
|
|
|
| Range of displayed temperatures |
|
0 °C-99 °C (±1 °C) |
|
|
| Regulating of electric heating element |
From 30 °C to 80 °C (±2 °C) |
|
|